A PHP Error was encountered

Severity: 8192

Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice

Filename: drivers/Session_files_driver.php

Line Number: 132

Backtrace:

File: /home4/tranding/public_html/ricoscientific.com/index.php
Line: 320
Function: require_once

A PHP Error was encountered

Severity: 8192

Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice

Filename: drivers/Session_files_driver.php

Line Number: 290

Backtrace:

File: /home4/tranding/public_html/ricoscientific.com/index.php
Line: 320
Function: require_once

A PHP Error was encountered

Severity: 8192

Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice

Filename: drivers/Session_files_driver.php

Line Number: 164

Backtrace:

File: /home4/tranding/public_html/ricoscientific.com/index.php
Line: 320
Function: require_once

A PHP Error was encountered

Severity: 8192

Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice

Filename: drivers/Session_files_driver.php

Line Number: 233

Backtrace:

File: /home4/tranding/public_html/ricoscientific.com/index.php
Line: 320
Function: require_once

A PHP Error was encountered

Severity: 8192

Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice

Filename: drivers/Session_files_driver.php

Line Number: 313

Backtrace:

File: /home4/tranding/public_html/ricoscientific.com/index.php
Line: 320
Function: require_once

A PHP Error was encountered

Severity: 8192

Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice

Filename: drivers/Session_files_driver.php

Line Number: 354

Backtrace:

File: /home4/tranding/public_html/ricoscientific.com/index.php
Line: 320
Function: require_once

A PHP Error was encountered

Severity: 8192

Message: strpos(): Passing null to parameter #1 ($haystack) of type string is deprecated

Filename: libraries/Javascript.php

Line Number: 657

Backtrace:

File: /home4/tranding/public_html/ricoscientific.com/index.php
Line: 320
Function: require_once

Microbiological Bacteriological Incubator Manufacturer in india | RICO

Bacteriological Incubator

Bacteriological incubators of RICO are designed to maintain optimum temperature conditions for the development of microbiological cultures in a controlled environment.

We specialize in both standard and optimized models, especially to meet the challenging demands of various specialized research applications.

Special Features

  • The outer chamber is made of dough powder of light steel.
  • The interior chamber is made of aluminum or stainless steel (304) sheet.
  • The composite convection system ensures a good mix, strong dispersion and maintains high temperature uniformity inside the chamber.
  • Door has a double viewing window which inspects the sample placed inside the chamber without disturbing the thermal conditions.
  • Filling of mineral wool (insulation) in the middle of the outer body and inner chamber prevents thermal damage.
  • Door gasket fixed on a double walled door for proper sealing.
  • Heavy hinges with ball catcher, spring loaded door closing device. Door is duly insulated.
  • Adjustable two ventilation slides control the internal air / vapor circulation.
  • High-quality beam heat elements made from nicomed / colored wire are placed in the ribs on thebottom and sides for equal heat distribution.
  • There are ribs in the inner chamber to keep the shelves at convenient levels. Supplied with 2 or 3 removable shelves.
  • The temperature is controlled by the thermostat from 5°C to 100°C + 1°C. Fit on the front panel for easy operation.
  • Different program functions can be designed for different types of applications, and whenever used
  • The temperature is displayed by the digital LED in front of the oven with SV and PV display.
  • Front panel is provided with ON / OFF switch, temperature controller and indicator
  • supplied with cord and plug.
  • Operating voltage: 220V AC (50Hz).

Applications

  • Plant Cell Growth
  • Fermentation Studies
  • Bacterial Culturing
  • Mycology Studies

Technical Specifications

Model No. RSI/BI-28 RSI/BI-43 RSI/BI-90 RSI/BI-105 RSI/BI-120 RSI/BI-215 RSI/BI-240 RSI/BI-325
Inner Chamber in MM (WxHxD) 300x300x300 355x355x355 455x455x455 455x605x 455 455 x605 x 605 605x605x605 605x910x455 605x910 x605
Inches Conversion 12 x 12 x 12 14 x 14 x 14 18 x 18 x 18 18 x 24x 18 18 x 24 x 24 24 x 24 x 24 24 x 36 x 18 24 x 36 x 24
Capacity 28 ltrs. 43 ltrs. 90 ltrs. 105 ltrs. 120 ltrs. 215 ltrs. 240 ltrs. 325 ltrs.
Heating Load 0.50 KW 0.50 KW 1.00 KW 1.00 KW 1.50 KW 1. 50 KW 1.50 KW 2.00 KW
No. of Shelves 2 2 2 2 2 2 3 3
Temp. Range 5oC above ambient to 70oC
Temp. Controller Hydraulic type capillary thermostat.
Temp. Accuracy +1oC.
Temp. Display Thru L-shaped prismatic thermometer.
Air Circulation

By F. H. P. motor fitted with blower

Timer Facility By Mechanical Timer up to 2 Hours.
Fan Speed The speed can be regulated by the regulator.

Customizable sizes are also available