A PHP Error was encountered

Severity: 8192

Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice

Filename: drivers/Session_files_driver.php

Line Number: 132

Backtrace:

File: /home4/tranding/public_html/ricoscientific.com/index.php
Line: 320
Function: require_once

A PHP Error was encountered

Severity: 8192

Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice

Filename: drivers/Session_files_driver.php

Line Number: 290

Backtrace:

File: /home4/tranding/public_html/ricoscientific.com/index.php
Line: 320
Function: require_once

A PHP Error was encountered

Severity: 8192

Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice

Filename: drivers/Session_files_driver.php

Line Number: 164

Backtrace:

File: /home4/tranding/public_html/ricoscientific.com/index.php
Line: 320
Function: require_once

A PHP Error was encountered

Severity: 8192

Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice

Filename: drivers/Session_files_driver.php

Line Number: 233

Backtrace:

File: /home4/tranding/public_html/ricoscientific.com/index.php
Line: 320
Function: require_once

A PHP Error was encountered

Severity: 8192

Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice

Filename: drivers/Session_files_driver.php

Line Number: 313

Backtrace:

File: /home4/tranding/public_html/ricoscientific.com/index.php
Line: 320
Function: require_once

A PHP Error was encountered

Severity: 8192

Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice

Filename: drivers/Session_files_driver.php

Line Number: 354

Backtrace:

File: /home4/tranding/public_html/ricoscientific.com/index.php
Line: 320
Function: require_once

A PHP Error was encountered

Severity: 8192

Message: strpos(): Passing null to parameter #1 ($haystack) of type string is deprecated

Filename: libraries/Javascript.php

Line Number: 657

Backtrace:

File: /home4/tranding/public_html/ricoscientific.com/index.php
Line: 320
Function: require_once

Laboratory Hot Air Oven Manufacturer in India - RICO

Laboratory Hot Air Oven Manufacturer in India - RICO

RICO uses dry heat to stave off hot air oven articles. The hot air oven uses a microprocessor to control the temperature. Double walled insulation preserves heat and preserves energy. These do not require water and unlike autoclaves, there is not much pressure inside the oven, so that they become safe to work. We are both experts in standard and customized models, specially designed to meet the challenging demands of various personal and special research applications.

Special Features

  • Up to 250°C
  • Accurate and even heat distribution
  • Safe for operators and samples
  • Removable Stainless Steel Shelves
  • On heat and current safety
  • Ventilation of gases
  • Temperature protection according to Din 12880 Class 3.1
  • Low noise fan
  • Construction of double wall
  • Digital temperature controller
  • Forcible communications
  • Imported heating element

Applications

  • Annealing
  • Die-bond Curing
  • Drying
  • Polyimide Baking
  • Sterilizing

Technical Specifications

Model No:

Inner Chamber
(W x D x H)

Volume
(Liters)

Load
(KW)

Shelves
(No’s)

RSI/HAO-301

300 x 300 x 300 mm

30

1.5

2

RSI/HAO-302

355 x 355 x 355 mm

45

1.5

2

RSI/HAO-303

455 x 455 x 455 mm

95

2.0

2

RSI/HAO-304

455 x 455 x 605 mm

125

2.2

3

RSI/HAO-305

605 x 605 x 605 mm

224

2.5

3

RSI/HAO-306

605 x 455 x 910 mm

252

2.5

3

RSI/HAO-307   

605 x 605 x 910 mm

336

3.0

3

Temp. Range

5°C above ambient to 250°C maximum

Temp. Accuracy

+ / - 2°C

Temperature Uniformity

+ / - 1°C

Controls

PID Controller

Temp. Display

LED Display

Sensor

PT-100

Heating Element

Nichrome wire / Kanthal A1

Safety device

On temperature protection
Electric leakage breaker
Temperature protection according to Din 12880 Class 3.1

Exterior Chamber

MS powder coated

Interior Chamber

304 stainless steel

Insulation

Mineral Wool

Doors

Solid doors w/ silicone rubber gasket & lock

Shelves

2 – 3 Stainless steel shelves (Removable)

Air Circulation

Forced air circulation

Power Supply

220 Volts

Optional

- Dot Matrix Printer interface
- Temperature chart recorder
- PLC Controller
- Stainless steel outer cabinet
- Audio / visual alarm
- IQ, OQ, PQ and DQ documentation
- Extra shelves
- Heating Thermostat
- NABL Certification
- Manufacturer calibration certificate